EMC DES-4122 exam is a specialist-level certification exam designed for individuals who want to demonstrate their knowledge and skills in implementing and managing Dell EMC PowerEdge servers. DES-4122 exam is intended for implementation engineers, technical support professionals, and system administrators who work with Dell EMC PowerEdge servers in their daily operations. The DES-4122 exam is one of the most sought-after certifications in the IT industry and is recognized globally.
NEW QUESTION # 27
Which mobile devices are supported by Quick Sync 2.0 in 14G PowerEdge servers?
- A. iOS and Android devices only
- B. Android devices only
- C. iOS, Android, and Windows Phone devices
- D. iOS devices only
Answer: A
NEW QUESTION # 28
A technician wants to remotely log in to a server but finds that the IDRAC virtual Console feature Is not available. Use the simulator to explore the system. What Is the cause of this Issue?

Note: It is necessary to dose (x) the simulator window before you can select a response to this question.
- A. Operating system not installed on remote server
- B. The server has been powered down
- C. There are more than the maximum number of active sessions
- D. The Virtual Console is disabled
Answer: B
NEW QUESTION # 29
What happened on April 30, 2019?

Note: It is necessary to dose (x) the simulator window before you can select a response to this question.
- A. Option D
- B. Option A
- C. Option C
- D. Option B
Answer: C
NEW QUESTION # 30
A Dell EMC PowerEdge server logs the following CPU Machine Check error CPU1 IERR What action might solve the problem?
- A. Update the Intel driver
- B. Reseat the IDSDM
- C. Remove flea power
- D. Swap the PERC controller
Answer: A
NEW QUESTION # 31
A technician installs eight servers into a fully operational rack with top of rack switch Each server has a quad 1Gb NIC and redundant power supplies The company uses iDRAC in shared LOM mode with LOM1 as the selected NIC What should the technician do to verify iDRAC connectivity on each server?
- A. iDRAC dedicated NIC port is cabled and the link light is green
- B. iDRAC Datacenter license is installed.
- C. iDRAC Enterprise license is installed
- D. Ethernet port LOM1 is cabled and the link light is green.
Answer: D
NEW QUESTION # 32
What can be done using in-band management?
- A. Firmware and driver updates
- B. Agentless discovery
- C. Network bandwidth optimization
- D. Remote access
Answer: C
NEW QUESTION # 33
A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.
What action should a technician take to help accomplish this goal?
- A. Enable the Collect System Inventory On Restart (CSIOR) attribute
- B. Install and configure a repository manager
- C. Configure servers to access the remote firmware repository
- D. Enable the Match Firmware of Replaced Part setting in the system BIOS
Answer: C
NEW QUESTION # 34
What are the default settings used when applying firmware and a configuration to a replaced part using the Lifecycle Controller?
- A. Firmware: Upgrade to latest available version
Configuration Apply always - B. Firmware: Match firmware of replaced part
Configuration Apply always - C. Firmware Allow version upgrade only
Configuration: Disabled - D. Firmware Disabled
Configuration Apply only if firmware match
Answer: B
NEW QUESTION # 35
A technician is sent on-site to troubleshoot a server that produced an error message during the most recent POST, but then completed the POST and booted to the operating system. The user cannot remember the specific error and no entry was made in the error log relating to this error.
How can the technician find out what the error message was?
- A. Access the Lifecycle Controller and view the last boot cycle video capture entry
- B. Reload the BIOS firmware
- C. Access the iDRAC and view the last boot cycle video capture entry
- D. Export the Server profile and analyze for any POST errors
Answer: A
NEW QUESTION # 36
A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.
What action should a technician take to help accomplish this goal?
- A. Configure servers to access the remote firmware repository
- B. Enable the Collect System Inventory On Restart (CSIOR) attribute
- C. Install and configure a repository manager
- D. Enable the Match Firmware of Replaced Part setting in the system BIOS
Answer: D
NEW QUESTION # 37
A Dell EMC PowerEdge 14G server uses Intel OPTANE DC Persistent Memory in App Direct mode. What is the minimum size DIMM supported for this type of memory?
- A. 64 GB
- B. 256 GB
- C. 128 GB
- D. 512 GB
Answer: C
NEW QUESTION # 38
What is a requirement to operate GPUs in a Dell EMC PowerEdge R740 server?
- A. All GPU cards must be of the same type but can be a different model
- B. All GPU cards must be of the same type and model
- C. All GPU cards must be installed on the same riser card.
- D. All GPU cards must be installed at the same time
Answer: B
NEW QUESTION # 39
What is a requirement to operate GPUs in a Dell EMC PowerEdge R740 server?
- A. All GPU cards must be of the same type but can be a different model
- B. All GPU cards must be of the same type and model
- C. All GPU cards must be installed at the same time
- D. All GPU cards must be installed on the same riser card.
Answer: C
NEW QUESTION # 40
A technician working with a Dell EMC PowerEdge 1 take corrective action?
- A. Check the System Event Log
Check PSU LED
Do a virtual reseat of the iDRAC - B. Check the System Event Log
Check PSU LED
Reseat the PSU - C. Check the LCC Log
Check PSU LED
Reseat the PSU - D. Check the LCC Log
Check PSU LED
Reseat the CPU
Answer: A
NEW QUESTION # 41
What is the Open Compute Project (OCP) card used for in a Dell EMC PowerEdge server?
- A. Provide a hot-swap component
- B. Consume a PCIe slot
- C. Flexibility to choose interconnects
- D. Fixed networking card
Answer: C
NEW QUESTION # 42
Match each status LED indicator on the Dell EMC 14G PowerEdge server with its corresponding condition.
Answer:
Explanation:
NEW QUESTION # 43
How can the ePSA be accessed?
- A. OMSA
- B. iDRAC
- C. Lifecycle Controller
- D. VMware vSphere plug-in
Answer: B
NEW QUESTION # 44
What is the drive characteristic of a BOSS M.2 drive in a Dell EMC PowerEdge server?
- A. Quad-level cell
- B. Write Intensive
- C. Read Intensive
- D. Single-level cell
Answer: D
NEW QUESTION # 45
Match each RAID level to its characteristic.
Answer:
Explanation:
NEW QUESTION # 46
A technician working with a Dell EMC PowerEdge 14G server observes the PCIe indicator turn solid amber What should they do to take corrective action upon checking the System Event log?
A)
B)
C)
D)
- A. Option D
- B. Option A
- C. Option C
- D. Option B
Answer: C
NEW QUESTION # 47
A Dell EMC PowerEdge R740 server requires a vFlash SD card urgently. Additional vFlash Cards and components from other servers are available.
What is the recommended solution?
- A. Reuse an existing vFlash SD card from either a 13G or 14G server
- B. Use a configuration option to convert BOSS to a virtual vFlash
- C. Use a configuration option to convert an NVMe drive to a virtual vFlash
- D. Reuse an existing vFlash SD card from a 14G server
Answer: D
NEW QUESTION # 48
Refer to the exhibit.
Match each callout to the Dell EMC PowerEdge server model shown.
Answer:
Explanation:
NEW QUESTION # 49
Match each RAID level to its characteristic.
Answer:
Explanation:
NEW QUESTION # 50
......